Picture of Watt Meter Plus DC Inline Power Analyzer, 75 A, 8 AWG, SB50 Connectors
Watt Meter Plus DC Inline Power Analyzer, 75 A, 8 AWG, SB50 Connectors
  • $76.99
  • In Stock
  • SKU: WMPlus-SB50

Watt Meter Plus DC Inline Power Analyzer, 75 A, 8 AWG, SB50 Connectors

Plugs into Anderson SB50 cables to measure DC loads up to 75 A continuous, 140 A peak. Shows amps, volts, watts, amp-hours, watt-hours, peaks and minimum volts, with an auto timer. 8 AWG high-temperature leads, 5 to 60 V DC; reads to 0 V on the auxiliary cable, sold separately. Read Full Description
$76.99
Availability: In Stock
SKU: WMPlus-SB50
GTIN: 840128905104

The Watt Meter Plus with SB50 connectors is a 75 A inline DC watt meter and power analyzer for Anderson SB50 cables. Its 8 AWG high-temperature silicone leads carry 75 A continuous, 140 A peak, on 5 to 60 V DC. DC only.

Anderson SB50 on Both Leads

SB50 connectors come fitted to the 8 AWG leads, rated 392 °F (200 °C): no crimping.

Eight Readings Plus a Timer

Amps, volts and watts are always shown. Amp-hours, watt-hours, peak amps, minimum volts and peak watts follow in turn, reset at power-up; an auto timer records how long the last draw lasted.

Which Watt Meter?

ModelContinuous / peak currentLead wireConnectorsAuto timer
Watt Meter, Powerpole45 A / 100 A12 AWGPowerpole (mates PP15, PP30, PP45)
Watt Meter, Bare Wire45 A / 100 A12 AWGBare ends, fit your own
Watt Meter, MC445 A / 100 A12 AWGMC4 solar
Watt Meter Plus, Bare Wire75 A / 140 A8 AWG, high-temperatureBare ends, fit your ownYes
Watt Meter Plus, SB5075 A / 140 A8 AWG, high-temperatureAnderson SB50Yes

The Watt Meter Plus, SB50 on this page is the one for Anderson SB50 systems running 45 to 75 A continuous.

Key specifications

Maximum continuous current75 A
Maximum peak current140 A
Voltage range5 to 60 V DC, 0 to 60 V DC on auxiliary power
Amp-hour range0 to 65 Ah
Watt-hour range0 to 6,554 Wh
Resolution0.01 A (1 to 140 A), 0.01 V, 0.1 W
TimerDuration of the last consumption
Lead wire8 AWG silicone, high-temperature, 392 °F (200 °C)
Lead length4 in (101.60 mm) per side
ConnectorsAnderson SB50, pre-installed
DisplayBlue backlit LCD
Dimensions4.4 x 1.8 x 1.0 in (111 x 45 x 26 mm)
Weight0.28 lb (126 g)
Warranty1 year limited

Wiring it in

The meter measures one direction, source to load; reverse current damages it. The standard hookup: a 5 to 60 V DC source on one SB50, the load on the other.

Watt Meter Plus with SB50 connectors wired between a 5 to 60 V DC source and a load

Under 5 V, a battery on the auxiliary input powers the meter so it reads from 0 V.

Watt Meter Plus with SB50 connectors powered by an auxiliary battery while it measures a 0 to 60 V battery and load

To log a charge, put the battery on the load side and the charger on the source side.

Watt Meter Plus with SB50 connectors between a battery charger and the battery being charged

Common questions

Will it plug into my connectors?

Only into Anderson SB50. Its housings are gray, which mate with gray and black SB50 housings; Powerpole and other SB sizes do not mate.

Why is the screen blank?

On its own power it needs 5 V; for lower or slow-rising sources, add the auxiliary cable, sold separately.

The Downloads section of this page has the Plus user manual.

Environmental & Legislation

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.

Customer Reviews

Great Meter By Bradley S.
This is a great meter.  At 75 amps continuous and 140 amps peak.  Since all my connections us SB50 or SB75 amps this is basically plug and play.  The ability to capture peak amperage is  very useful.  The meters on my VS-70 AP power supply just aren’t fast enough catch peaks.

The following are two suggestions for making this unit better.
1.  The leads are a tad too short (2 3/4 inch from housing to SB50).  A total length of 6 inches would be perfect.
2.  Mounting issue:   Unfortunately there isn’t a screw/bolt hold to mount the device and doesn’t appear there’s a place to add one.  A bracket of some kind that the meter could snap into would be perfect.  Unfortunately the only solution is to use either double stick tape or a Velcro fastener like found on your EZ-Pass.  Otherwise the unit just lays on the surface basically flat which makes reading it difficult at best….because the leads are so short (2 3/4 inch from housing to back of SB50) to the SB50 connector mounting is made more difficult because the meter wants to twist to accommodate the SB50 connectors.  I’ve taken the unit apart and could make the leads longer using the same type 8 gauge silicon wire used in this product.  I understand the reason for keeping the leads short to maintain the 75 amps continuous and 140 peak…all of which is a moot point if the leads coming from the source to the load are too long or the gauge wire is insufficient to carry that kind of amperage.  In addition I wouldn’t want to run the max rated 120amps through a SB50 connector…8 gauge wire is rated at 125-150 amps at 13.8 volts 0-4 foot.   Replacing the wire isn’t for the faint of heart.  It will take a temperature controlled soldering iron at about 750-800 degrees with a medium sized chisel tip and pre-tinning the replacement wire.  Since my power supply is only rated at 70 amps ICS the SB50 and 8 guage wire work fine.

Brad
South of Pittsburg
Was this review helpful? Yes No (18/0)
Nice Meter By Mark R.
Thanks to Powerwerx for letting me know that I could use my 75amp Power pole connectors in place of the SB50's.
That worked great!
Was this review helpful? Yes No (11/1)
Write a review of this product and share your opinion with others.
Not Good Needs That Special Something Average, Ordinary That's Good Stuff Perfect. It doesn't get any better
The most useful comments contain specific examples about:
  • How you use the product
  • Things that are great about it
  • Things that aren't so great about it