Busbar Integrated Battery Monitoring
The Lynx Shunt VE.Can is a positive and negative busbar, battery monitor and a fuse holder for the main system fuse. The Lynx Shunt VE.Can can communicate via VE.Can with a GX device, like the Cerbo GX. The Lynx Shunt VE.Can ships with two RJ45 VE.Can terminators, that are used when connecting to a GX device. The Lynx Shunt VE.Can is designed to hold a ANL/ANN fuse. The fuse needs to be purchased separately. For more info see section Fusing in the Lynx Shunt VE.Can manual.
The Lynx Distribution System
The Lynx Distribution System is a modular busbar system that incorporates DC connections, distribution, fusing, battery monitoring and/or Lithium battery management. The Lynx Distribution System consist of the following parts:
• Lynx Power In - A positive and negative busbar with 4 connections for batteries or DC equipment.
• Lynx Distributor - A positive and negative busbar with 4 fused connections for batteries or DC equipment together with fuse monitoring.
• Lynx Shunt VE.Can - A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE.Can communication for monitoring and setup with a GX device.
• Lynx Smart BMS - For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor that is driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring. It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE.Can communication for monitoring with a GX device and the VRM portal.
Specifications
| Voltage Range | 9-70Vdc |
|---|
| Supported System Voltages | 12, 24 or 48V |
|---|
| Reverse Polarity Protection | No |
|---|
| Current Rating | 1000A continuous |
|---|
| Power Consumption | 60mA @ 12V / 33mA @ 24V / 20mA @ 48V |
|---|
| Busbar Connections | M10 |
|---|
| VE.Can | RJ45 and RJ45 terminator |
|---|
| Power Supply Connection to Lynx Distributor | RJ10 (a RJ10 cable ships with each Lynx Distributor) |
|---|
| Temperature Sensor Connection | Screw terminal |
|---|
| Relay Connection | Screw terminal |
|---|
| Enclosure Material | ABS |
|---|
| Enclosure Dimensions (h x w x d) | 7.5 x 6.7 x 3.2 in (190 x 180 x 80 mm) |
|---|
| Unit Weight | 3.1 lbs (1.4 kg) |
|---|
| Busbar Material | Tinned copper |
|---|
| Operating Temperature Range | -40°F to +140°F (-40°C to +60°C) |
|---|
| Protection Class | IP22 |
|---|