The Victron Orion 48/12-60A is a 48 V to 12 V DC-DC converter for running 12 V equipment from a 48 V battery bank. It delivers 60 A continuous at an output you set between 10 and 15 V, for the lights, radios, pumps and audio in a golf cart, solar system, boat or RV.
60 A Continuous output
38 to 66 V DC Input range
10 to 15 V Adjustable output
92 % Efficiency
Key specifications
| Part number | ORI481260020 |
|---|
| Input voltage range | 38 to 66 V DC |
|---|
| Under-voltage shutdown / restart | 38 V / 40 V |
|---|
| Output voltage | 10 to 15 V, adjustable (factory setting 13.2 V) |
|---|
| Continuous / maximum output current | 60 A / 65 A |
|---|
| Efficiency | 92 % |
|---|
| Off-load current | Less than 20 mA |
|---|
| Galvanic isolation | No (non-isolated) |
|---|
| Cooling | Fan assisted, temperature controlled |
|---|
| Parallel operation | Up to 5 units |
|---|
| Operating temperature | -4 to 131 °F (-20 to 55 °C), derated above 104 °F (40 °C) |
|---|
| DC connections | M6 bolts |
|---|
| Protection rating | IP20 |
|---|
| Weight | 2.0 lb (0.9 kg) |
|---|
| Dimensions (H x W x D) | 2.6 x 3.5 x 7.7 in (65 x 88 x 195 mm) |
|---|
Setting it up
Mount it in a cool, dry, ventilated spot: the case is IP20, so it belongs inside a cabinet or compartment, away from spray. Connect the negative cables first. Victron warns that a poor negative connection can push the output voltage too high.
The output leaves the factory at 13.2 V. To change it, turn the potentiometer with a small slotted screwdriver, clockwise to raise it, while a small load is connected.
For remote on/off, replace the wire bridge on the green connector with a small switch (under 100 mA), or feed its right-hand terminal from the 48 V supply through an ignition or run/stop switch. No heavy switch is needed in the 48 V cable.
Common questions
What circuit protection does it need?
A fuse or breaker on the 48 V input cable and another on the 12 V output cable, each sized for its wire. On the input side, use parts rated for 48 V DC.
Is it isolated?
No. The 48 V and 12 V sides share the negative, which suits a system wired on one common negative. A system that must keep the two sides apart needs an isolated converter.
Can it charge a 12 V battery?
Victron rates it to buffer-charge a battery: set the output to the battery's charge or float voltage. It holds that one voltage with no charge stages, so it keeps an accessory battery topped up rather than replacing a charger.
The datasheet, the instruction sheet and the dimension drawing are in the Downloads section of this page.