The Victron Lynx Smart BMS 500 NG (M10) is the battery management system for Victron Lithium NG batteries, in 12, 24 or 48 V banks of up to 50. It bolts to the other M10 Lynx modules, such as the Lynx Distributor and Lynx Power In.
500 A Contactor, Pre-Charge
Rated 500 A continuous and 600 A for 5 minutes, the safety contactor sits between bank and system, with a pre-charge circuit built in.
Battery Monitor Built In
A shunt inside reads state of charge, voltage, current and time to go, so a Lynx system with this BMS needs no Lynx Shunt.
Charge and Load Control
Allow-to-charge and allow-to-discharge contacts, a relay and DVCC through a GX device switch chargers and loads off when the batteries ask.
Bluetooth and VE.Can
Set it up and read each cell in VictronConnect. A GX device on VE.Can adds VRM and steers Victron inverter/chargers and solar chargers.
Key specifications
| Part number | LYN034160310 |
|---|
| Batteries | Victron Lithium NG only (12.8, 25.6 and 51.2 V) |
|---|
| System voltage | 12, 24 or 48 V (supply 9 to 60 V DC) |
|---|
| Maximum bank | 50 batteries (25 at 48 V) |
|---|
| Contactor, continuous / 5 minutes | 500 A / 600 A |
|---|
| Control outputs | Charge / discharge contacts 0.5 A, relay 2 A, at 60 V DC |
|---|
| Communication | Bluetooth, VE.Can (2x RJ45), RJ10 to up to 4 Lynx Distributors |
|---|
| Busbar connections | M10 |
|---|
| Protection rating | IP22 |
|---|
| Operating temperature | -40 to 140 °F (-40 to 60 °C) |
|---|
| Dimensions (h x w x d) | 7.48 x 7.09 x 3.15 in (190 x 180 x 80 mm) |
|---|
| Weight | 4.19 lb (1.9 kg) |
|---|
Wiring it into a Lynx system
Batteries go on the left side (normal mounting position) and every load and charger on the right, negatives included, or the state of charge reads wrong. The NG batteries' M8 BMS cables daisy-chain, the first and last battery to the BMS. Tighten the busbar joints to 292.07 in-lb (33 N-m).
Common questions
Will it work with Victron Lithium Smart batteries?
No. Victron makes it for Lithium NG batteries only; its Lithium Smart batteries use a different BMS.
Does it fuse the battery?
No. It warns on overcurrent but is not a fuse: fuse the system separately, for example with a Lynx Distributor, keeping the fuses' total within the lowest-rated Lynx module.
Does it need a GX device?
Not to run. A GX device on VE.Can lets it control Victron chargers and inverter/chargers and report to VRM. Bluetooth, once off, can only be turned back on from a GX device.
The Lynx Smart BMS NG datasheet and manual and the dimension drawing for this model are in the Downloads section of this page.